Short Description:
● Conventional trunk cable and daisy chain cable options
● Globally certified forc-ETL-US, SAATUV VDE-ARN-N 4105,VDE 0126 G83/2CEI 021,IEC61727,EN50438
● Designed for frame mount and rail mount solutions
● BDM-800-wifi Built-in WiFi for remote monitoring BDM-800 Integrated monitoring and power line communication with BDG-256 gateway
● High efficiency 95.5% CEC
● NEMA-6/1P-66/1P-67 enclosure rating
● Integrated grounding for easy installation
Model |
BDM 800 |
Input DC |
|
Recommended Max PV Power (Wp) |
1200 |
Recommended Max DC Open Circuit Voltage (Vdc) |
60 |
Max DC Input Current (Adc) |
17×2 |
MPPT Tracking Accuracy |
>99.5% |
MPPT Tracking Range (Vdc) |
22-55 |
Isc PV (absolute maximum) (Adc) |
20 x 2 |
Maximum Inverter Backfeed Current to the Array(Adc) |
0 |
Output AC |
|
Rated AC Output Power (Wp) |
800 |
Nominal Power Grid Voltage (Vac) |
768 / 700 / 750 |
Allowable Power Grid Voltage (Vac) |
211V-264* / 183V-228* / configurable* |
Allowable Power Grid Frequency (Hz) |
59.3 a 60.5* / configurable |
THD |
<3% (at rated power) |
Power Factor (cos phi, fixed) |
-0.99>0.9 (adjustable) / 0.8un>0.8ov |
Rated Output Current (Aac) |
3.2 / 3.36 / 3.26 |
Current (inrush)(Peak and Duration) |
9.4A, 15us |
Nominal Frequency (Hz) |
60 / 50 |
Maximum Output Fault Current (Aac) |
9.6A peak |
Maximum Output Overcurrent Protection (Aac) |
10 |
Maximum Number of Units Per Branch (20A)(All NEC adjustment factors have been considered) |
2005/5/5 |
Syistem efficiency |
|
Weighted Averaged Efficiency (CEC) |
95.50% |
Night Time Tare Loss (Wp) |
0.11 |
Protection functions |
|
Over/Under Voltage Protection |
Yes |
Over/Under Frequency Protection |
Yes |
Anti-Islanding Protection |
Yes |
Over Current Protection |
Yes |
Reverse DC Polarity Protection |
Yes |
Overload Protection |
Yes |
Protection Degree |
NEMA-6 / IP-66 / IP-67 |
Ambient Temperature |
-40°F to +149°F (-40°C to +65°C) |
Operating Temperature |
-40°F to +185°F (-40°C to +85°C) |
Display |
LED LIGHT |
Communications |
Power Line |
Dimension (W-H-D) |
8.8” x 8.2” x 1.38” (268x250x42 mm) |
Weight |
6.4 lbs. (2.9 kg) |
Environment Category |
Indoor and outdoor |
Wet Location |
Suitable |
Pollution Degree |
PD 3 |
Overvoltage Category |
II(PV), III (AC MAINS) |
Product Safety Compliance |
UL 1741 |
Grid Code Compliance* (Refer to the label for the detailed grid code comliance) |
IEEE 1547 |
1.Micro inverters are connected to solar panels,Each micro-inverter connects four components at the same time
2.The micro-inverter converts the direct current output from the solar panel into the daily usable alternating current
3.The data collector (DTU) is used to collect the operating data of the micro-inverter, and the power generation can be monitored on the S-Miles Cloud platform
4.HM micro-inverters can provide reactive power compensation and are equipped with external antennas to enhance communication.